Lifescan OneTouch Profile blood glucose monitor Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Nie Lifescan OneTouch Profile blood glucose monitor. Lifescan OneTouch Profile blood glucose monitor User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Owner’s Booklet

™™Owner’s BookletComplete Diabetes Tracking SystemFor diabetes and life.

Strona 2 - CAUTION

IMPORTANT TEST STRIP INFORMATION• One Touch™Test Strips are sensitive to heat and light. Keep them sealed in the origi-nal vial and store in a cool, d

Strona 3 - TABLE OF CONTENTS

INSERTSTRIPCODE 9CODE 97:26AM 1/06/00CODING THE METERCode numbers are used to calibrate themeter with the test strips for reliableresults.Make sure y

Strona 4

Step 2: Match the Code Numbers.If the code number on the displaymatches the code number on your teststrip vial, you may begin testing. If the two code

Strona 5 - INTRODUCTION

It is very important that you do the fol-lowing two simple checks routinely tomake sure you get accurate results.CHECK STRIP TESTA purple and white ch

Strona 6 - PRECAUTIONS AND LIMITATIONS

Step 1: Turn on the meter. The code number will appear on thedisplay. Next, INSERT CODE 10 (forexample) STRIP will appear. Step 2: Insert the check st

Strona 7 - BLOOD GLUCOSE METER

The display will show ✓OK if your result fallswithin the correct checkstrip range printed on theback of your meter. If the reading is notwithin the re

Strona 8

IMPORTANT CHECK STRIP INFORMATION• If your check strip result is repeatedly out of range, your meter may not beworking properly. Do not use the meter

Strona 9 - TEST STRIPS

CONTROL SOLUTION TESTOne Touch™Normal Control Solution isused instead of blood to tell you that themeter and test strips are working togeth-er properl

Strona 10 - • One Touch

IMPORTANT CONTROL SOLUTION TEST INFORMATION• Use only One Touch™Normal Control Solution.• Check the expiration date of the control solution. Do not us

Strona 11 - 7:26AM 1/06/00

The control solution test follows thenormal test procedure, using controlsolution instead of blood.Step 1: Turn on the meter.The code number, time, an

Strona 12

CAUTION Before using any productto test your blood glucose (blood sugar),read all instructions andpractise the test. Do allquality control checksas di

Strona 13 - CHECK STRIP TEST

Step 3: Apply control solution.After the test strip is in the test stripholder, WAIT PLEASE appears for amoment, then APPLY SAMPLEappears. Shake the c

Strona 14

20Step 4: The result appears within 45 seconds.Compare the control solution test resultwith the control solution range printedon the One Touch™Test St

Strona 15 - 7:40AM 1/06/00

21TESTING YOUR BLOODDETAILED TEST PROCEDUREChoose a clean, dry work surface. Make sure you have all the items needed to test.Release ButtonEjection/Co

Strona 16

22CAUTION: To reduce the chance of infection:• Never share a lancet with anotherperson.• Always use a new, sterile LifeScanLancet. Lancets are for sin

Strona 17 - CONTROL SOLUTION TEST

23Step 2: Adjust Puncture Depth.Twist the depth adjustment knoblocated at the end of the Penlet™PlusSampler to desired puncture setting. Smaller bumps

Strona 18

24Step 3: Cock the Penlet™Plus Sampler.Slide the ejection/cocking control backuntil you hear a click. If it does not click,the Penlet Plus Sampler may

Strona 19 - 7:50AM 1

25•Choose a spot on the side of a differentfinger each time you test. Repeatedpunctures in the same spot may causesoreness and calluses.Step 5: Get a

Strona 20

26Gently massage your finger to obtainthe required blood volume. Proceedwith your blood glucose test (see “Step-by-Step Test Procedure”, page 29).Hold

Strona 21 - 7:52AM 1/06/00

27Optional: To replacethe protective disk onthe lancet, place the diskon a hard surface andpush the exposed tipinto the protective disk.Caution: Alwa

Strona 22 - TESTING YOUR BLOOD

28Return the ejection/cocking control tothe middle position. Replace the cap.Point the lancet down and away from you.Push forward on the ejection/cock

Strona 23 - GETTING A DROP OF BLOOD

Introduction 4Precautions and limitations 5One Touch™Profile™Blood Glucose Meter 6One Touch™Test Strips 8SETTING THE SYSTEM Coding the meter 10Check s

Strona 24

STEP- BY- STEP TEST PROCEDUREStep 1: Turn on the meter.Press the power button. A code numberand the date and time will appear. Thecode number must mat

Strona 25

WAITPLEASEAPPLY SAMPLEStep 2: Insert a test strip.Next, INSERT CODE 10 (for exam-ple) STRIP appears. Slide a test stripinto the strip holder, notched

Strona 26

Many times, the meter can detect if thereis not enough blood and will showbut you should also look at the test stripto make sure.Step 3: Apply blood t

Strona 27

32Checking the amount of blood on thetest strip.•Remove the teststrip from the meterand look at the testspot. It should stillhave a wet shinydrop tha

Strona 28

The meter displays results above 600 mg/dLor 33.3 mmol/L as HI DANGER. Aresult that reads HI DANGER meansvery high blood glucose (severehyperglycemia)

Strona 29 - CLEANING THE PENLET

Test results below 60 mg/dL or 3.3 mmol/L mean your blood glucoseis low (hypoglycemia).IMPORTANT: If you get a HI DAN-GER result or a result below 60

Strona 30 - PROCEDURE

EVENT LABELLINGImmediately after testing your blood,you may want to mark your glucosereadings with event labels. The One Touch™ Profile™meter has 15 s

Strona 31 - CODE 10 STRIP

It will appear on the meter display withyour test result, alternating with thetime and date.36To select an event label, press the C but-ton while the

Strona 32

ENTERING THE MEMORYTurn on the meter. Press the M buttonto enter the meter memory. The word MEMORY will appear briefly.MEMORYMCThe One Touch™Profile™M

Strona 33

The very first time you turn on yourmeter and press the M button, the fol-lowing message will appear, showing thatthere are no results stored in the m

Strona 34 - HImmol/L

Time and date 43Event averaging 44Insulin prompt 45Insulin programming 46Display language 48Time format 49Date format 49Decimal separator 50Unit of m

Strona 35 - 3,3mmol/L

You can change or add event labels orinsulin information stored in memorywhile they are displayed on the meter.To delete an insulin record, simplysele

Strona 36 - EVENT LABELLING

SET-UPOPTIONS MODEYou can change, or in some cases turn off,11 features of your One Touch™Profile™Meter to suit your individual needs. • Beep prompts

Strona 37 - 7,2mmol/L

• Use the M button to scroll throughthe options or move within an option.• If you want to change an option set-ting, use the C button.• Once you have

Strona 38 - USING THE METER MEMORY

BEEP PROMPTSThe One Touch™Profile™Meter usesbeeping tones to signal various steps inthe meter procedures.The beep option is seen immediatelyafter ente

Strona 39 - 4,4mmol/L

TIME AND DATEIn the set-up mode, use the M buttonto choose the Time option. The currenttime will show. Press the C button tochange the time; the hour

Strona 40

EVENT AVERAGINGIn the set-up mode, usethe M button to choosethe event averagingoption. Press the C button toturn on the event averag-ing option.ONAVGM

Strona 41 - OPTIONS MODE

Step 1: Change the insulin type.When a type of insulin, SHORT forexample, is flashing on the meter,press the C button until your first typeof insulina

Strona 42 - 08.15.00

Step 2: Change the insulin units.When the units area is flashing ‘00’, pressthe C buttonuntil yourinsulin doseis displayed.Press the M button again an

Strona 43 - BEEP PROMPTS

After you have moved through eacharea, the complete record will be dis-played for two seconds, followed byanother insulin programming screen.You may t

Strona 44 - M-MOVE C-CHANGE

The One Touch Profile Meter is pre-setto prompt you in English. To changethe display language, enter the set-upmode. Use the M button to choose thedis

Strona 45 - 6,7mmol/L

INTRODUCTIONThe One Touch™Profile™GlucoseMonitoring System is for people withdiabetes who need to check the level ofglucose (sugar) in their blood. To

Strona 46 - INSULIN PROMPT

DATE FORMATThe meter is pre-set to display the dateas month-day-year. For example: June01, 2000 reads as 6-01-00. You can setthe meter to display day-

Strona 47 - INSULIN PROGRAMMING

DECIMAL SEPARATORThe meter is pre-set to display mil-limoles per litre (mmol/L) and basalinsulin rate values using a decimalpoint. This option allows

Strona 48 - CARBOHYDRATE COUNTING

EXITING THE SET-UP MODEAfter you have completed viewing orchanging your option settings, simplyturn the meter off. The meter will auto-matically exit

Strona 49 - DISPLAY LANGUAGE

The display messages that appear on your One Touch™Profile™Meter will guide youthrough testing procedures, alert you to any problems as they occur, an

Strona 50 - TIME FORMAT

45. . . . 0106 MG/DL or 5.9 MMOL/L A blood test has been completed. This indicates a blood glucose(for example) resultwhen the meter is set for mg/dL

Strona 51 - DECIMAL SEPARATOR

60 MG/DL or 3.3 MMOL/L(for example)8:01 AM 6-01-00alternating with60 MG/DL or 3.3 MMOL/L(for example)DO YOU NEED A SNACK240 MG/DL or 13.3 MMOL/L(for e

Strona 52

55MESSAGE APPEARS WHENHI MG/DL or HI MMOL/LDANGER 8:01 AM 6-01-00alternating withHI MG/DL or HI MMOL/LCALL. DR.TEST KETONESYour blood glucose test res

Strona 53 - SOLVING PROBLEMS

When any of the following messages appear, there is a problem with your One Touch™Profile™Meter or the way in which you are performing a test. In most

Strona 54

57PROBLEM1. There is dirt, blood, or linton the test area.2. Your hand or an object cov-ered the test area during testing.3. The meter was used in ver

Strona 55

58PROBLEMThe sample was applied beforethe words APPLY SAMPLEappeared.1. The test strip moved duringthe test.2. The test strip was not insert-ed correc

Strona 56

PRECAUTIONS AND LIMITATIONS• If you experience symptoms that are not consistent with your blood glucose results,and you have carefully followed the pr

Strona 57 - ERROR MESSAGES

59PROBLEM6. The check strip procedurewas incorrect.7. The meter may not be operating correctly.1. The blood or control solu-tion sample was too small

Strona 58 - (for example)

60PROBLEM1. If appearing when you turnyour meter on, your meter mayhave an electronic problem.2. If appearing at the end of atest, your meter may have

Strona 59

61PROBLEMThe last check strip test wasoutside the acceptable rangeand an acceptable repeat testwas not performed.The last test failed after thecountdo

Strona 60

To keep your One Touch™Profile™Blood Glucose Meter in good operatingcondition, follow these simple rules:• Keep the test strip holder and test areacle

Strona 61

CLEANING THE METERDO A DAILY CHECK: Look throughthe small hole in the test strip holder tomake sure there is no lint, dirt, or bloodblocking it.If the

Strona 62

Step 2: Clean the test strip holder.Wash the test strip holder with soap andwater.Clean the underside of the test strip hold-er. Using a cotton swab,

Strona 63 - TAKING CARE OF YOUR METER

Rub the test area with a cotton swab orsoft cloth dampened with water toremove all blood, dirt, or lint from thetest area. If necessary, a mild liquid

Strona 64 - CLEANING THE METER

Press forward on the base of the test stripholder to be sure it is properly in place.You are now ready to do a check striptest. If the check strip wil

Strona 65 - CAUTION:

WhenBATTRY`REPLACE NOWappears flashing onthe display, the meter will no longer giveresults and you must replace the batter-ies before you can perform

Strona 66

Step 3: Remove the old batteries. Remove the oldbatteries by gentlyslapping the meteragainst the palm ofyour hand. Nevertap the meteragainst a hard su

Strona 67 - REPLACING THE BATTERIES

ONE TOUCH™PROFILE™BLOOD GLUCOSE METERStudy this diagram to become familiar with all of the parts of your One Touch™Profile™Meter.6Battery Compartment(

Strona 68

PERFORMANCE CHARACTERISTICSPower Supply: 2 x 1.5V. alkaline batteries (AAA) Battery Life: Approximately one year when testing up to four times a day.R

Strona 69

WARRANTYFive-Year WarrantyIf, at any time during the first five yearsafter purchase, the meter does not workfor any reason (except for obvious abuse),

Strona 70 - SPECIFICATIONS

SHORT Short insulinINTERM Intermediate insulinLONG Long insulinXLONG Extra long insulin30/70 Mixture 30% Short and 70% Intermediate and 50/50 Mixture

Strona 71 - WARRANTY

1995The enclosed LifeScan Blood Glucose Meter, as an electro-medical device, has been thoroughlytested and found to comply with the essential requirem

Strona 72 - INSULIN TYPES

For further information on LifeScan products, please call your authorized LifeScan representative.© LifeScan, Inc. 2000Milpitas, California 95035, U.S

Strona 73

On/off button. This button turns the meteron and off.Display. This is where you read the simplemessages that guide you through test-ing, setting optio

Strona 74

ONE TOUCH™TEST STRIPSWhen blood is applied to the white testspot on the test strip, compounds on thetest strip react with the blood to form ablue colo

Komentarze do niniejszej Instrukcji

Brak uwag