Lifescan One Touch ll Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Pomiary, testowanie i kontrola Lifescan One Touch ll. Lifescan One Touch ll User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
®
OWNER’S BOOKLET
MANUEL DU PROPRIÉTAIRE
BLOOD GLUCOSE MONITORING SYSTEM
SYSTÈME DE CONTRÔLE DE LA GLYCÉMIE
LSI-97-051 OT2.bklt.C.Eg 10/8/97 3:10 PM Page 1 (1,1)
Przeglądanie stron 0
1 2 3 4 5 6 ... 86 87

Podsumowanie treści

Strona 1 - MANUEL DU PROPRIÉTAIRE

®OWNER’S BOOKLETMANUEL DU PROPRIÉTAIREBLOOD GLUCOSE MONITORING SYSTEMSYSTÈME DE CONTRÔLE DE LA GLYCÉMIELSI-97-051 OT2.bklt.C.Eg 10/8/97 3:10 PM Page

Strona 2

the LifeScan TechnicalService Department via thetoll-free numbers listedbelow:Canada 1 800 663-5521U.S.A. 1 800 227-8862MEASUREMENTCONVERSION. The ONE

Strona 3 - Solution - Blue Formula

systems. (See Chapter 9,Setting Date, Time, andOther Special Functions.)TEST STRIPS. ONE TOUCH®Test Strips come in amoisture-proof, light-protected vi

Strona 4

There are two ways to makesure your ONE TOUCH®IISystem is working properly. The Check Strip is used tocheck that the Meter isoperating properly. ONE T

Strona 5 - The ONE TOUCH

If either of these problemsoccur, you should firstattempt to determine thecause of the problem byreviewing the instructionsin this Owner’s Booklet. If

Strona 6

can purchase ONE TOUCH®Normal Glucose ControlSolution — Blue Formulafrom your AuthorizedLifeScan Distributor or retail pharmacy.To do a Control Soluti

Strona 7

Checking the Meter withthe Check StripA plastic (purple and white)Check Strip is includedwith your ONE TOUCH®IIMeter. The Check Strip isused to check

Strona 8 - 2. GETTING STARTED

How to use the Check StripStep 1:PressOn/OffButton.code 7(example)will appearon thedisplay.(The codenumberdoes not need to be set todo a Check Strip t

Strona 9

Step 3:Wheninsertside 2appears,turn theCheck Stripover andwith Side 2(white)facing up,insert itback into the Test StripHolder, notched end first.The M

Strona 10

Chapter 8, Cleaning andMaintaining the Meter. Forfurther assistance, call theLifeScan Technical ServiceDepartment toll-free.Canada 1 800 663-5521U.S.A

Strona 11 - TEST SUMMARY

u✔Do not expose the CheckStrip to direct sunlight forextended periods of time.u✔If you lose or damagethe Check Strip, call theLifeScan Technical Servi

Strona 12 - 3. CHECKING THE SYSTEM

®Blood Glucose Monitoring SystemOWNER’S BOOKLETLSI-97-051 OT2.bklt.C.Eg 10/8/97 3:10 PM Page 3 (1,1)

Strona 13

Set the code before usingthe Meter for the first timeand every time you open anew package or change to adifferent package of TestStrips.Step 1:Press O

Strona 14 - (example)

Step 2:Match thecodenumberPress the CodeButton (C).code 7(example)will reappear on the displayfor several seconds. Withcode 7(example)on the display,

Strona 15 - Front Back

The PENLET®II AutomaticBlood Sampler is an easy,safe way to get a good dropof blood.PENLET®IIHow to use the PENLET II:Step 1: Insert a Lancet1. Remove

Strona 16

3. Remove the LancetProtective Disk by holdingthe Lancet firmly and gentlytwisting off the Disk.4. Replace the PENLET®IIcap.Note: The PENLET IIinclude

Strona 17

Step 2: Cock the PENLET®IIHolding the lower portionof the body of the PENLETII, pull out the dark graysliding barrel until a click isheard. If you do

Strona 18

Choose a spot on the side ofa different finger each timeyou take a blood sample.Repeated punctures in thesame spot can make yourfinger sore and callou

Strona 19

Step 4: Remove theLancetAlways usecautionwhen re-moving theLancet.After theblood glu-cose test,remove thePENLET®II cap. Grip thedark gray T-shaped pro

Strona 20 - 4. CODING THE METER

You can test your bloodglucose by following thesethree simple steps:Step 1: PressOn/OffButtonStep 2: Insert TestStripStep 3: ApplybloodsampleBe sure t

Strona 21

Step-by-stepinstructionsChoose a clean,dry work surface.Gather togetherall the materialsyou will need fora test:ONE TOUCH®IIMeterONE TOUCH®Test Strips

Strona 22 - Sliding Barrel

IMPORTANT: Beforetesting, the Test StripHolder and Test Area of theMeter must be clean andlint-free. (See Chapter 8,Cleaning and Maintainingthe Meter,

Strona 23 - Deep Penetration

6-VOLT1✔RNormal Glucose ControlSolution - Blue Formula“J” size Battery (installed) Memory Button “M” Code Button “C”Check StripTest StripTest SpotLanc

Strona 24

Step 2:Insert Test Strip1. Remove a Test Strip fromthe package. Do not touchthe white Test Spot (a smallwhite circle in the center ofthe Strip). If us

Strona 25

3. waitwill appear on the displayfor a few moments. Then,4.applysampleappears on the display, andremains for five minutes oruntil you apply blood to t

Strona 26

it is pushed back to itsoriginal position as quicklyas possible.u✔Do not smear the bloodon the Test Spot or apply asecond drop after the testhas begun

Strona 27 - PAS D'ALCOOL

with MM before the result(or 0–600 mg/dL, the unit ofmeasure used in the UnitedStates). Results above 33.3mmol/L (600 mg/dL) aredisplayed as high.To s

Strona 28 - “M” Button “C” Button

2. Look atthe TestSpotwhere youappliedthe bloodsample. Itshouldstill havea wet,shinydrop which completely fillsthe circle. If the bloodsample has a du

Strona 29

• 34 •7. TROUBLESHOOTINGSpecial display messages during testingIf at any time during the test procedurethe display reads error or not ok, there isa pr

Strona 30 - Test Spot

The sample was appliedbefore apply sampleappeared on the display.(See Chapter 6, TestingYour Blood.)There has been an error inthe test procedure. Some

Strona 31

• 36 •Go Back to Step 1 in Chapter 6, TestingYour Blood, and start over with a newTest Strip. Make sure you are followingthe instructions carefully.Th

Strona 32

The last Check Stripreading was outside theacceptable range ofresults. The Check Strip test must be repeated. (See Chapter 3,Checking the System.) If

Strona 33

• 38 •What to do if you feel your test resultmay be wrong:If you follow the instructions in thisbooklet, you will find that it is easy toget accurate

Strona 34 - Front Side

Dear ONE TOUCH®II Owner:Congratulations! You’ve selected a verysophisticated, yet easy-to-use, blood glucosemonitoring system for home testing. YourON

Strona 35 - 7. TROUBLESHOOTING

number displayed on the Meter byrepeatedly pressing Code Button “C” orholding it down until the correct codeappears in the display. (See Chapter 4,Cod

Strona 36

• 40 •u✔You may have a special physicalcondition, such as extreme dehydration,which is affecting your results. (SeeChapter 12, Questions and Answers,

Strona 37

Your ONE TOUCH®II Meteris simple to use and easy tomaintain. However, like allprecision instruments itmust be handled carefullyand cleaned frequently

Strona 38

u✔Avoid exposing theMeter or the Test Strips toextremes of temperature orhumidity for extendedperiods of time. Forexample, avoid leaving theMeter or T

Strona 39

3. Perform a Check Striptest by following theinstructions in Chapter 3,Checking the System.Cleaning the MeterThe Test Strip Holder mustbe removed for

Strona 40

Step 2: Clean Test StripHolder1. Wash the Test StripHolder with soap and water.2. Clean the underside ofthe Test Strip Holder andcheck the small hole

Strona 41

1. Check the clear protectivecoating over the Meteroptics to make sure it is notscratched or damaged.2. Use a cotton swab or softcloth dampened with w

Strona 42

Step 4: Replace Test StripHolder1. Hook the bottom of theTest Strip Holder onto thesquare notch on the Meter.2. Place each thumb on theraised dots and

Strona 43

Battery ReplacementThe Metercomeswith one J-size (6v)Duracell®brandalkaline battery alreadyinstalled. The batteryshould last about one yearwith typica

Strona 44

Whenbattryappears on the display, theMeter will no longer giveresults, and you mustreplace the battery beforeyou can perform anothertest.A dead batter

Strona 45

The ONE TOUCH®II System is intended for in vitro diagnostic use only. (Thislegally required statement simply means that the Meter should be used onlyf

Strona 46

3. With your thumb, firmlypush the left side of thebattery door to the rightuntil it is released from theclasp, as indicated on thedoor.4. Completely

Strona 47

6. To replace the batterydoor, insert the tab on theright side of the door intothe slot in the batterycompartment.7. Swing the left side of thedoor ov

Strona 48

Your ONE TOUCH®II Meterhas special functions whichenable you to customize theMeter to meet your ownspecial needs. The Meterallows you to:• Set the clo

Strona 49

• Select AM/PM or 24:00time. The Meter is set at thefactory in AM/PM time.•Select the type of datamanagement system that the Meter will communicatewit

Strona 50 - CMV0943AA

You may also want tocustomize some of the otherfeatures mentioned above,based on your own needs.The following pages de-scribe how to set the dateand t

Strona 51

Using the “M” and “C” Buttons on the top of your Meter, follow the instructions in the chart to set the clock in your Meter.How the Chart WorksThe “C”

Strona 52

Setting Date and TimeCCCCCCCMMMMM With the Meterturned off, pressand hold (C) Press and release (ON/OFF) Release(C) Yearflashes Press (C)to ch

Strona 53

There are several specialfeatures you may choose to personalize your ONE TOUCH®II Meter. The following section willtell you how to set the beepfeature

Strona 54

The Meter is set at thefactory to display messagesin English. If you wish tochange the display toanother language, follow theinstructions on the chart

Strona 55 - How the Chart Works

Setting the date format(Date Format Mode)Your Meter is set at thefactory to display themonth, day, and year (inthat order) with each bloodglucose resu

Strona 56 - Setting Date and Time

TABLE OF CONTENTS 1. Tips for Getting Good Results 62. Getting Started 73. Checking the System 114. Coding the Meter 195. Getting a Drop of Blood 216.

Strona 57

select thecorrectmode for the kind ofdata man-agementsystem youare using.The Meter is set at the factoryin the RS-232 DataManage-ment Mode.In the RS-2

Strona 58

Using the “M” and “C” Buttons located on top of your meter,follow the directional arrows through the following chart.How the Chart WorksThe “M” Button

Strona 59

Options, and Data Management InterfaceMMUnit of MeasureModeDecimal Point/Comma ModeDate FormatModeAM/PM/24:00ModeData ManagementModeBaud RateModeDISPL

Strona 60

Your ONE TOUCH®II Meterautomatically stores up to250 test results, the date andtime of those results, plusan Event code, if selected.The Meter will no

Strona 61 - DISPLAYS

3. The wordmemoryappears briefly, followed byav 6 . 2(example)This number is the averageof your blood glucoseresults for the past 14 days.Check Strip

Strona 62

6. Press “M” again, and theresult of your most recenttest appears, for example:mm 5 . 2(example)A 3 .9(example)indicates a Check Stripresult.c 5 .

Strona 63

Selecting Event numbersYou may choose to mark theblood glucose reading withan Event number (1–9). Thisallows you or yourhealthcare professional toanal

Strona 64 - (June 11, 1994)

Event 7. Readings duringillnessEvent 8. Readings duringhypoglycemiasymptomsEvent 9. Readings duringhyperglycemiasymptomsYou may select an Eventnumber:

Strona 65

To cancel an Event number:mm 6 . 2 mm 6 . 2event6 event6(example)will alternate in the display.Press “C” Button repeatedlyuntilevent9is reached. Press

Strona 66

The following are messagesthat may appear on theMeter display. If you get amessage that is not listedbelow, it is likely that theMeter was accidentall

Strona 67

u✔Carefully read thisOwner’s Booklet and allother instructional materialprovided with your bloodglucose monitoring systemand test supplies.u✔Clean you

Strona 68

Recalling Tests from MeterMemory.)battryappears when the battery istoo low to perform anothertest. (See Battery Replace-ment in Chapter 8, Cleaningand

Strona 69

error1retestappears if the sample wasapplied before applysample appeared on thedisplay. (See Chapter 6,Testing Your Blood.)error2retestappears if you

Strona 70

highappears when a test result isabove 33.3 mmol/L or 600mg/dL. (See Chapter 12,Questions and Answers.)Important: a HIGH resultindicates severe hyper-

Strona 71

nodataappears if you press theMemory M Button whenthere are no results stored.not okappears when there is anelectronic problem withyour Meter. Call th

Strona 72

waitappears while the Meter isperforming some internalchecks. Wait until applysample appears to continue.(See Chapter 6, Testing YourBlood.)45 . . .0m

Strona 73

The second message is thetime the test was done(3:21PM). The third messageis the result 5.9 mmol/L(MM 5.9) as shown here inmmol/L. The fourth messagem

Strona 74 - .3 or mm 6 , 3

12. QUESTIONS AND ANSWERSIn the following pages, we’ve provided answers to some ofthe most common questions people have about home bloodglucose monito

Strona 75

Q. What clinicalinformation should ahealthcare professional beaware of when using theONE TOUCH®II Meter?A. For use in hospitals,institutions, and clin

Strona 76 - 12. QUESTIONS AND ANSWERS

Test results can alsoindicate whether yourdiabetes is changing in ways that might require an adjustment in yourtreatment program.Always consult yourhe

Strona 77 - A. No doubt your health

blood. Touch the drop ofblood lightly to the middleof the Test Spot to fill theentire spot. The drop ofblood should have a shinysurface over the entir

Strona 78

2. GETTING STARTEDBefore you read about the test procedure, please studythis diagram to becomefamiliar with the variousparts of your ONE TOUCH®IIMeter

Strona 79 - A. There are two very

Q. What should I do if testresults seem unusually lowor high?A. First, troubleshoot byeliminating any of thesepotential problems:u✔Clean your Meter Te

Strona 80 - A. Remember, the test

“How do I feel?”“Do I have symptoms of lowblood sugar (hypoglycemia)or high blood sugar(hyperglycemia)?”“What have I eaten?”“How much exercise have I

Strona 81

factors which could lead tosevere dehydration:• Vomiting and diarrhea• Prescription drugs, e.g.,diuretics• Inability to recognize orrespond to “thirst

Strona 82 - A. The goal of diabetes

glucose values for yourindividual treatment planshould be determined withyour healthcare professional.If your blood glucose testresults remain consist

Strona 83 - A. Many healthcare

Another reason for variationmay be that the Meter testwas not done within 10 or15 minutes of the laboratorytest. Because blood glucoselevels can chang

Strona 84

PerformanceCharacteristics:See ONE TOUCH®Test Strip package insert for ONE TOUCH®II Systemaccuracy and precision.Power Supply:One Duracell®brandalkali

Strona 85 - 13. SPECIFICATIONS

30-Day Money-BackGuaranteeIf you are not fully satisfiedwith the ONE TOUCH®IISystem, a full refund maybe obtained by calling aLifeScan TechnicalRepres

Strona 86 - 14. GUARANTEE AND WARRANTY

4. The warranty policy doesnot apply to the performanceof the ONE TOUCH®IIMeter when used with any test strip other thanONE TOUCH®Test Strips, or when

Strona 87 - AW 051-568-53A

ON/OFF BUTTON. Thisbutton turns the Meter on and off. DISPLAY. This is where youread your test results andthe simple messages thathelp guide you throu

Komentarze do niniejszej Instrukcji

Brak uwag